DLS-9 High Temperature Sensor

A K & T Type Thermocouple Sensor, works with both GW-2 & GW-3 Hubs.

DLS-9
Hot Probe supplied with DLS-9

Unit ships with an interchangeable standard high temperature K Type Probe end. This sensor is preferred for Cooking/Oven use etc. (Please note you only put the Probe end in the Oven). You can change the probe end if they are damaged, we also supply some different probe ends depending on your use case. (Sous Vide or Pie warmer etc).


To change the Sensor type between K & T, will require an email to support@sm8a.com.au to remotely change this configuration. (dashboard option coming soon).


This model can also be supplied in a Dual Sensor Model if required.


To turn on Sensor press and hold the button for 3 seconds or until the Status Light & LCD is on.

To turn off Sensor press and hold the button for 3 seconds or until the Status Light & LCD is off.

Specification Item  Feature 
Battery  Built-in 4000mAh/3.6V 
Measure Media  Ambient air 
Range of Thermocouple measuring 

K type thermocouple: -200℃ to 1370℃

T type thermocouple: -200℃ to 400 ℃ 

Accuracy of Thermocouple 

>100℃ (-148℉):±1℃(±1℉) 

<100℃ (-148℉):±2℃(±3.6℉) 

Working environment -30℃~+60℃;0%RH ~ 85%RH(non condensing) 
RF Frequency  915 
Modulation  LoRa 
Maximum Range in Open Area  2KM 
Transmit Power  20dbm(auto adjustable) 
Transmit Interval  every 15 Minutes (user definable coming soon)
Low Voltage Alarm  Dashboard only
Temp/RH Alarm  Dashboard only
Stand-by Current  <5uA 
IP Level  IP54 
Memory Capacity  50000 
Battery Life 

3 years (in 15mins interval) at room temperature.

In -35C Freezers normally about 18 months max.

N.W.  135g 
Dimension  106mm*57mm*33mm 
DLS-9 LCD Panel
NO.  Function  Indication 
LORA icon  LORA Sensor 
Transmission icon  It flashes when sending data,and then off 
Temperature alarm icon  Normal:√ Alarm:×  (Not Used)
Running status  ▷ Start running 
Temperature icon  Upper limit:↑ Lower limit:↓ Upper Lower limit:↑↓ (Not Used)
RSSI signal icon 

Very strong signal 

Strong signal 

Good signal 

General signal 

Poor signal 

The RSSI value is updated every time the gateway response after receiving the data, so the RSSI value is not displayed,if you don't turn on ACK or no response 

Battery level 

Full battery 

High battery 

Medium 

Low 

Temperature 

Unit: ℃,℉ optional

When abnormal, it displays ------ 

Thermocouple number 

When "T1" displays, it indicates LCD shows the data of the left thermocouple; 

When"T2"displays,it indicates LCD shows the data of the right thermocouple. (If Dual Model)